DETAILS OF ANALYSIS
This is an analysis of a typical
wall section of the Granite Mountain Reserve Project. The typical wall
section consists of a layer of concrete of thickness a (1.5 in.), a layer
of polysicyanurate of thickness b (4 in.) and a second identical layer
of concrete. Thermocouples are located, as indicated in the figure, at
the inside surface of the wall, in the center of the inside layer of concrete
and the insulation layer, at the interface between the insulation layer
and the outside layer of concrete, and at the outside surface of concrete.
Temperatures (°F) are measured each hour at these points, designated
T1,T2,T3, T4 and T5.
Section of 3 -
D wall panel.
Dimensions are same as above. Heat fluxes defined in analysis are
q1, q2, q3 and q4. Arrows associated with the heat fluxes indicate the
direction of positive heat flux.