Disaster
Proof Homes
|
Fire Protection
The photo on
the right is your typical wood framed home burning to the ground.
If you look close you can see the wood studs!
|
 |
  
The above home was
built in Malibu, California with the Tridipanel System including floors,
walls, ceilings and roof structure. The owner's previous home at this
location was burned to the ground. The solution to this problem was solved
by using Tridipanels.
Fire Ratings
For Tridipanel
Tridipanel has the following fire-resistance ratings (ratings
are valid for fire exposure from either side). Fire-rating is derived
from the wire mesh gauge in combination with cement thickness (see chart
below). The insulation core Type I polystyrene demonstrated a flame spread
index of 25 or less and a smoke developed rating of 450 or less when tested
in accordance with ASTM-E84. The modified polystyrene core will not burn
and does not contain ozone-damaging chlorofluorocarbons (CFC's) in the
manufacturing process of products.
- 2.5" polystyrene
core with 1.50" cement each side = 1.5 Hours
- 2.5" polystyrene
core with 2.00" cement each side = 2.0.Hours
- 2.5" polystyrene
core with 3.1/8" cement each side = 4.0 Hours
The fire rating
increases with greater quantities of cement applied to each side. The
polystyrene core will not burn.